Home > Components > Flow Control System

    TJP-3A Programmable Syringe Pump

    Controller and drive unit are separated.  With the programmable function, you can customize complex infusion/withdrawal process, such as stepped infusion, combination constant speed and ramped sp

    1. description

    Controller and drive unit are separated.  With the programmable function, you can customize complex infusion/withdrawal process, such as stepped infusion, combination constant speed and ramped speed infusion, trigger dispense or periodic dispense.

    Flow rates:0.138μl/min-52.94ml/min

    Max. Number of Channels:1

    Applications:

    For high precision fluid dosing, especially for laboratorial application.



    Product Instruction:

    Controller and drive unit are separated.  With the programmable function, you can customize complex infusion/withdrawal process, such as stepped infusion, combination constant speed and ramped speed infusion, trigger dispense or periodic dispense. 

    Main Functions and Features

    - User-defined syringe: Storing 4 inner diameters of user-defined syringe 
    - Linear force output: > 90 N 
    - Adopt membrane keypad, easy to operate 
    - Memory function: Storing the running parameters automatically 
    - Signal outputs: Start/Stop output, cw/ccw output (Open Collector) 
    - Calibration: Acquire accurate volume through calibration 
    - Fast forward & fast reverse: Infusion or withdrawal at the max. speed (158.8 mm/min)

    Technical Specifications

    - Max. Infusion Distance: 90 mm 
    - Acceptable Sample Syringe: 5 ?L - 60 mL 
    - Linear Speed: 7.9 ?m/min - 79.4 mm/min 
    - Adjusting Resolution: 7.9 ?L/min 
    - Distance Resolution: 0.165 ?m 
    - Linear Force: > 90 N 
    - Setting Mode: Membrane keypad and rotary coded switch 
    - Control Accuracy: < +/- 0.5% in condition of 30% of the full stroke 
    - Display: 128x64 graphic LCD 
    - External Control Interface: Start/Stop control, fast forward control, fast reverse control 
    - Communication Interface: RS485 
    - Power Supply: AC 100 V - 240 V or DC12V 
    - Power Consumption: < 10W 
    - Operating Condition: Temperature 0 to 40°C; relative humidity < 80% 
    - Controller Dimensions (Lx W x H) : 170 x 108 x 70 (mm) 
    - Controller Weight: 0.8 Kg 
    - Drive Unit Dimensions (L x W x H): 245 x 100x 95 (mm) 
    - Drive Unit Weight: 1.3 Kg

    Other parameters

    Contoller

    (Product Code)

    Driver Unit

    (Product Code)

    Syringe (ml)

    Syringe ID

    (mm)

    Flow Rate

    (μl/min-ml/min)

    TJP-3A
    (05.03.13A)
    W0109-1B
    (05.03.02A)
    14.720.139-1.39
    29.000.505-5.05
    513.101.07-10.7
    1016.601.718-17.18
    2019.002.251-22.51
    3023.003.298-32.98
    6029.145.295-52.95



    Tag:   Programmable Syringe Pump